Huawei inverter maximum output power

When SUN2000-100KTL-H1 operates at grid voltage 0.9 p.u. and ambient temperature ≤ 35°C, the output power can reach 100kW (when PF=1) or 100kVA. The power of SUN2000 inverter doesn't derate when altitude ≤ 4000m.
Customer Service >>

Smart Energy Controller SUN2000-3-10KTL-M1

SOLAR.HUAWEI /MEA Smart Energy Controller SUN2000-3-10KTL-M1 Efficiency [%] Maximum output current 13.6 A 15 A 15 A 15 A 15 A 15 A Power factor range 0.8 leading 0.8 lagging *1 Inverter max input PV power is 20,000 Wp when long strings are designed and fully connected with SUN2000-450W-P power optimizers.

Technical Specifications

Rated active power. 100 kW. Maximum apparent power. 100 kVA at 40ºC; 90 kVA at 50ºC. Maximum active power (cosφ = 1) 100 kW. Rated output voltage. 800 V AC, 3W+PE. Rated output current. 72.9 A. Supported power grid frequency. 60 Hz. Maximum output current. 72.9 A. Power factor. 0.8 leading to 0.8 lagging. Maximum total harmonic distortion

SUN2000-330KTL-H1 Smart String Inverter Technical

Support OT / DT Terminal (Max. 400 mm²) IP 66 C5-Medium Transformerless European Efficiency Input Max. Input Voltage Number of MPPT Max. Current per MPPT Max. Short Circuit Current per MPPT Max. PV Inputs per MPPT S tar Vol ge M PT Op er ati ngVol R N omi n alI pu tV ge Output Nominal AC Active Power Max. AC Apparent Power Max. AC Active

Operations Related to the Special User

Maximum apparent power (kVA) Specifies the output upper threshold for the maximum apparent power to adapt to the capacity requirements of standard and customized inverters. If the maximum active power equals the value of Smax_limit, this parameter is not displayed. Maximum active power (kW)

Setting Active Power Control

Function Description. If Active power control mode is set to Unlimited, the inverter automatically runs with the rated output set to the maximum Output power.If it is set to Remote output control, the inverter remotely connects to the server of the electric power company to obtain scheduling information and controls the Maximum active power based on the mapping between the time

SUN2000-2-6-KTL-L1

SOLAR.HUAWEI /MEA Technical Specification SUN2000-2KTL-L1 SUN2000-3KTL-L1 SUN2000-3.68KTL-L1 SUN2000 Rated output power 2,000 W 3,000 W 3,680 W 4,000 W 4,600 W 5,000 W 5 6,000 W *2 Inverter max input PV power is 10,000 Wp when long strings are designed and fully connected with SUN2000-450W-P power optimizers.

(Optional) Setting Limited Feed-in Parameters

If the power fluctuates within the power raising threshold, the power is not adjusted. You are advised to set this parameter to 1%–2% of the total rated output power of the inverter. Active power output limit when meter fails. Specifies the derating value of the inverter active power by percentage. The active power percentage derating value

Using Huawei SUN2000 inverters with high /A ratios

2024-12-24 Huawei Confidential Page 1 of 2 Using Huawei SUN2000 inverters with high /A ratios When the total Watt-peak (Wp) power of the solar modules exceed the nominal AC power rating of the connected solar inverter, engineers typically refer to such a setup as an "oversized installation".

Power Parameters

PV output power. Total output power of PV arrays. PV output power-PV yield. Total yield of PV arrays in a given reporting period. Hourly: PV yield each hour. Daily: PV yield each day. Monthly: Total yield of each day in a month. Yearly: Total yield of each month in a year-Inverter yield. Yield of a plant. Hourly: Inverter output energy each hour

SUN2000-3-4-5-6KTL-L1 Specs | HUAWEI Smart

PV power 1. *1.The inverter max input PV power is 10,000 Wp when long strings are designed and fully connected with optimizers. Disclaimer: The preceding values are measured by an internal laboratory of Huawei in a

SUN2000-3-4-5-6KTL-L1 Specs | HUAWEI Smart PV Global

*1.The inverter max input PV power is 10,000 Wp when long strings are designed and fully connected with optimizers. Disclaimer: The preceding values are measured by an internal laboratory of Huawei in a specific environment. The actual values may vary with products, software versions, usage conditions, and environmental factors.

Smart Energy Controller

*1 Inverter max input PV power is 10,000 Wp when long strings are designed and fully connectedwith SUN2000-450W-P poweroptimizers. *2 Themaximuminputvoltage and operating voltage upperlimitwill be reduced to 495 V when inverter connects andworkswith LG battery.

SUN2000-100KTL-M1

Inverter Output Filter Output Relay EMI SPD L1 L2 L3 N PE SUN2000-100KTL-M1 @400 V 8 SUN2000-100KTL-M1. SOLAR.HUAWEI SUN2000-100KTL-M1 Technical Specification Technical Specification SUN2000-100KTL-M1 Efficiency Max. efficiency 98.8% @480 V, 98.6% @380 V / 400 V Output Nominal AC Active Power 100,000 W Max. AC

SUN5000-17-25K-MB0 Specs | HUAWEI Smart

*1.The maximum input voltage is the upper limit of the DC voltage. Any higher input DC voltage would probably damage inverter. *2.Any DC input voltage beyond the operating voltage range may result in inverter improper operating.

FusionSolar Residential & Commercial Datasheet

Huawei is a leading global provider of information and communications technology (ICT) infrastructure and smart devices. *2 Inverter max input PV power is 10,000 Wp when long strings are designed and fully connected with SUN2000-450W-P power optimizers. Maximum output current 15 A Power factor range 0.8 leading 0.8 lagging

String Inverter (SUN2000-30KTL-A)

Output Rated AC Active Power 30,000 W Max. AC Apparent Power 33,000 VA Max. AC Active Power (cosφ=1) 30,000 W Rated Output Voltage 277 V / 480 V, 3W+PE Rated AC Grid Frequency 50 Hz / 60 Hz Max. Output Current 40 A Adjustable Power Factor 0.8 LG 0.8 LD Max. Total Harmonic Distortion <3% Protection Input-side Disconnection Device Yes

De-rating Behavior and P-Q Curve of Inverter

2017-12-29 Huawei confidential information Page 3 5. Maximum Working Temperature vs. Altitude of SUN2000-60KTL-M0 (380/400Vac) Note: The maximum working temperature is the ambient temperature below which SUN2000 can output rated power without de-rating. When the altitude rises, the cooling capacity of the inverters de-rates.

SUN2000-3-10KTL-M1 (High Current Version)

Maximum output current; 13.6 A. 15 A; 15 A. 15 A; 15 A. 15 A; *1 Inverter max input PV power is 20,000 Wp when long strings are designed and fully connected with SUN2000-450W-P power optimizers . *2 The maximum input voltage is the upper limit of the DC voltage. Any higher input DC voltage would probably damage inverter.

iSitePower-M-5/10/15/20/25/30

Maximum output current 30 A Output power 6 kVA/5 kW Power factor 0.8 Overload capacity 102% ≤ Load ≤ 125% 30 s 125% < Load ≤ 150% 10 s >150%/short circuit 0.3 s Email: eu_inverter_support@huawei HUAWEI TECHNOLOGIES CO.,LTD Huawei Industrial Base Bantian Longgang Shenzhen 518129,P.R ina

Setting Reactive Power Control

When multiple time points are set, the solar inverter will run with the maximum power specified for the time point that is earlier than and the closest to the current system time. For example, if you add 00:00:00 and 12:00:00 on the WebUI and the current system current is 14:30:00, the solar inverter will run with the maximum power specified

About Huawei inverter maximum output power

About Huawei inverter maximum output power

When SUN2000-100KTL-H1 operates at grid voltage 0.9 p.u. and ambient temperature ≤ 35°C, the output power can reach 100kW (when PF=1) or 100kVA. The power of SUN2000 inverter doesn't derate when altitude ≤ 4000m.

At SolarCabinet Energy, we specialize in comprehensive outdoor cabinet solutions including communication cabinets, energy storage cabinets, energy storage systems, and renewable energy integration. Our innovative products are designed to meet the evolving demands of the global telecommunications, energy storage, and industrial power markets.

About Huawei inverter maximum output power video introduction

Our outdoor cabinet and energy storage system solutions support a diverse range of telecommunications, industrial, and commercial applications. We provide advanced energy storage technology that delivers reliable power for communication infrastructure, commercial operations, industrial facilities, emergency backup systems, grid support services, and remote power requirements. Our systems are engineered for optimal performance in various environmental conditions.

When you partner with SolarCabinet Energy, you gain access to our extensive portfolio of outdoor cabinet and energy storage products including complete outdoor cabinet solutions, communication cabinet systems, energy storage cabinets for rapid deployment, commercial energy storage solutions for businesses, and industrial storage systems. Our solutions feature high-efficiency lithium iron phosphate (LiFePO4) batteries, smart hybrid inverters, advanced battery management systems, and scalable energy solutions from 5kW to 2MWh capacity. Our technical team specializes in designing custom outdoor cabinet and energy storage solutions for your specific project requirements.

6 FAQs about [Huawei inverter maximum output power]

What is the maximum input PV power for a Huawei inverter?

Recommended max. PV power 1 *1.The inverter max input PV power is 10,000 Wp when long strings are designed and fully connected with optimizers. Disclaimer: The preceding values are measured by an internal laboratory of Huawei in a specific environment.

How much power can a solar inverter use?

Recommended max. PV power 1 *1 Inverter max input PV power is 20,000 Wp when long strings are designed and fully connected with SUN2000-450W-P power optimizers. *2 The maximum input voltage is the upper limit of the DC voltage. Any higher input DC voltage would probably damage inverter.

How do I adjust the power of my solar inverter?

On the home screen, tap Settings > Power adjustment and set inverter parameters. Specifies the output upper threshold for the maximum apparent power to adapt to the capacity requirements of standard and customized solar inverters. Specifies the output upper threshold for the maximum active power to adapt to different market requirements.

How do I control inverter output power percentage?

Inverter output power percentage is controlled by the SmartLogger when communication between the SmartLogger and the power meter is abnormal. Specifies whether the DO port is allowed to control switch-off. Set this parameter to the DO port that controls switch-off. Set this parameter to the DO port that controls switch-on.

What is a maximum input voltage?

Note a: The maximum input voltage is the maximum DC input voltage that the inverter can withstand. If the input voltage exceeds this value, the inverter may be damaged. Note b: If the input voltage is beyond the operating voltage range, the inverter cannot work properly.

What if the inverter has no output power?

When the inverter has no output power, set this parameter to Positive if the active power reading of the power meter is positive. Otherwise, set this parameter to Reverse. Total power: controls the total power at the grid-tied point to limit the power fed to the power grid.

More solar information

Contact SolarCabinet Energy

Submit your inquiry about solar power generation systems, battery energy storage cabinets, photovoltaic systems, commercial solar solutions, residential storage systems, solar industry solutions, energy storage applications, and solar battery technologies. Our solar power generation and battery storage experts will reply within 24 hours.